esc
Calculators

BTU and AC ton calculator:
room cooling or heating

Kitne ton ka AC chahiye? Type the room size and ceiling height, pick your climate, sun and number of people, and see the BTU/h, the tons and the AC size to look at.

ft
ft
ft
Cooling needed6,000 BTU/h0.5 ton · 1.76 kW
Room area
180 sq ft · 16.7 m²
Kilowatts
1.76 kW
Tons (12,000 BTU/h each)
0.5
AC size to look at
0.75 ton
Window / portable unit
6,000 BTU/h
  • Sizing rules: ENERGY STAR’s room-AC chart (8 ft ceiling) for mild climates; Indian makers’ charts (about 1 ton per 120 sq ft, 8–10 ft ceiling) for hot ones. Shade −10%, sun +10%, +600 BTU per extra person, +4,000 for a kitchen.
  • A unit far too big cools in short bursts and leaves the room damp; a top-floor room under a sunny roof may need the next size up.
More tools for PakistanIndia Other countries

How to use BTU and AC ton calculator

  1. 01Type the room sizeAnd ceiling height.
  2. 02Set climate and sunPeople, kitchen.
  3. 03Read BTU and tonsWith the AC size to look at.
File character arranging marked pages

Room size, then adjustments.

For mild climates the area is looked up in the ENERGY STAR room air conditioner chart (8 ft ceiling). For hot places like Pakistan, India and the Gulf it uses the makers’ rule of about 1 ton per 120 sq ft. Then: −10% for a shaded room, +10% for a sunny one, 600 BTU for each person above two, and 4,000 BTU for a kitchen.

At a glance

Price
Free. No sign-up, no watermark.
Privacy
Your text stays in your browser. Nothing is uploaded.
Works in
Chrome, Edge, Firefox and Safari, on phones and computers

Questions

What size AC for a 12 × 15 ft room?

That room is 180 sq ft. In a mild climate the ENERGY STAR chart gives 6,000 BTU/h (half a ton). In a hot city like Lahore or Delhi, at about 1 ton per 120 sq ft, it needs 18,000 BTU/h, a 1.5 ton AC.

How many BTU is 1 ton?

One ton of cooling is 12,000 BTU per hour (3.517 kW): the heat that melts a ton of ice in a day. A 1.5 ton AC is 18,000 BTU/h and a 2 ton is 24,000 BTU/h.

Is a bigger AC better?

No. An oversized unit cools the air quickly and switches off before it removes the moisture, so the room feels cold and clammy, and it costs more to run.

How is heating worked out?

With a rule of thumb of 30–60 BTU per sq ft depending on how cold your winters are, raised for ceilings above 8 ft. A heating engineer’s load calculation is more exact.

Is what I type sent anywhere?

No. The calculation runs in your browser and nothing you type leaves your device.